RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,084 products across 99 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Leather Chem

Ethylene Vinyl Acetate copolymer

Ethylene vinyl acetate EVA copolymers are used in extrusion film processes for applications including packaging, surface protection and greenhouse covers, and in photovoltaic cell encapsulation.
Part number
RXSOL-96-9603-025
Category
Leather Chem
Brand
RXSOL
RXSOL

Overview

Ethylene vinyl acetate (EVA) copolymers are used in extrusion film processes for applications including packaging, surface protection and greenhouse covers, and in photovoltaic cell encapsulation. EVA copolymers are used in molded caps and seals, footwear and car interiors. They are the base polymer in many adhesive resin formulations and in wire and electrical cables compounding. For the hot-melt adhesive needed to hold pages and covers together in bookbinding applications, low to medium MI and high VA grades are used to maximize cohesive strength and flexibility.RXSOL EVA is an ethylene vinyl acetate copolymer with 18% VA.

Technical specifications

Properties                                                    Typical Value  Unit

Test Method

Melt Index (190°C / 2.16 kg)  2.5 g/10 min ASTM D1238
Vinyl Acetate Content 18  wt% ASTM D5594 
Density 0.935  g/cm3 ASTM D1505
Vicat Softening Point 64  °C

ASTM D1525 

Melting Point 87 °C ASTM D3418 
Tensile Strength at Yield 5.2 MPa ASTM D638
Tensile Strength at Break 11 MPa ASTM D638
Elongation at Yield 260 % ASTM D638
Elongation at Break >800  %

ASTM D638

Flexural Modulus 60  MPa

ASTM D790

Hardness Shore A 76  

ASTM D2240

Hardness Shore D 36   ASTM D2240

Applications

RXSOL EVA can be used for blown or cast monolayer and coextruded films, or blended with other resins. Other grades can be used for molded or extruded liner seals inside plastic and metal bottle caps.

  • Adhesive Lamination
  • Barrier Food Packing
  • Coextrusion Coating
  • Compouding
  • Document Plastification
  • Extrusion Coating

Characteristics and notes

Benefit ::

  • Low seal initiation temperature for fast packaging speeds
  • Low shrink temperature
  • Greater adhesion than polyethylene (PE) to a variety of substrates/layers including polyolefins, PVS, PS and PET
  • Softer and clearer than PE
  • Enhanced flexibility
  • Increased impact strength
  • Improved puncture resistance
  • Excellent flex crack resistance
  • Excellent flow and caulking in seal area
  • Good bondage to PVdC in coextrusion processe

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name Ethylene Vinyl Acetate Copolymer
Part Number RXSOL-96-9603-025

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.

VASHI ,NEW BOMBAY 400703 INDIA

Branch : Kandla, Hazira, Mumbai, Chennai, Vizag, Kolkata , UAE & Oman

Phone +91 22 20871200 / 2087 1300 / 2087 1400
Fax +91 22 27612100 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Website www.rxmarine.com
Name     of        Substance                          Cas Number EC Number Wight %
Ethylene Vinyl Acetate Copolymer 24937-78-8    -------  100%

 

Signal  Word                                               None
Hazard Statements Not classified as dangerous for supply/use. The preparation does not meet the criteria for classification in accordance with Directive 1999/45/EC and Directive 1272/2008/EC.
Precautionary statements  prevention May form combustible dust-air mixtures.
Precautionary statements - response

Avoid skin contact. Avoid inhalation of hot resin fumes and vapors.

  

Eye Contact         

The product is an inert solid. Treat as for any foreign object in eye. Check for and remove any contact lenses. Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and  lower eyelids. Get medical attention immediately if eyes are irritated.

Skin Contact First aid is normally not required. For contact with hot products, immediately flush skin with plenty of cold water for at least 15 minutes to dissipate heat. Remove contaminated clothing and shoes. Treat as for skin burns. Get medical attention.
Inhalation: For exposure to dusts, vapors and/or aerosols formed at elevated temperatures, move exposed person to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately.
Ingestion: Not a likely route of exposure. Wash out mouth and water. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.

Extinguishing  media                        As appropriate for surrounding fire. Extinguish preferably with foam, carbon dioxide or dry chemical.
Unsuitable Extinguishing Media Do not use water jet or waterspray.
Suitable extinguishing media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Fire Fighting Protective Equipment A self contained breathing apparatus and suitable protective clothing should be worn in fire conditions.
Protective Equipment Use personal protective equipment.
Hazardous Decomposition
Product(s)
Combustion or thermal decomposition will evolve toxic and irritant vapours.
Advice for emergency responders Do not take action without proper training and emergency equipment. See Section 8 for additional information. Evacuate surrounding areas. Eliminate all ignition sources including flares and all open flames. Avoid all contact with spilled material. Maintain adequate ventilation and wear appropriate respiratory protection.

Spillage                              Sweep up, then place into a suitable container for disposal. Avoid generating dusty conditions. Provide ventilation.
Personal Protection Caution - spillages may be slippery. Ensure suitable personal protection (including respiratory protection) during removal of spillages. Dust clouds are sensitive to ignition by electrostatic discharge.
Enviromental Precaution Avoid dispersal of spilled material, runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).
Methods and materials for
containment and cleaning
Stop spill if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, surface waters, basements or confined areas. Wash spillage into effluent treatment plant. Contain and collect spillage using appropriate personal protective equipment. Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handing chemical products or if a risk assessment indicates this is necessary. Collect and contain spillage with non-combustible, absorbent material (e.g. sand, earth, vermiculite or diatomaceous earth) and place in a container for disposal according to local regulations. Use spark-proof tools and explosion proof equipment if flammable gasses, liquids or vapors are present in the spill area. Contaminated absorbent material may pose the same hazard(s) as the spilled product.

 

Handling                      Observe all label precautions. Use appropriate personal protective equipment (see section 8). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. To avoid fire or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before transferring material.
Storage

Keep only in the original container. Keep container tightly closed. Keep in a cool, well ventilated place. Keep away from heat and direct sunlight. This product should be kept away from naked flames and other sources of ignition.

Bulk storage should be in approved vessels, preferably steel that is grounded and vented Keep use containers tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination

Specific end uses No other additional special end uses are anticipated.

.

Engineering  Control   Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits.
Personal Protectiol Eye/face protection: Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to product dusts, liquid splashes or mists. Goggles should be worn where eye contact is possible.
Hand protection: Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is required.
Glove material: cotton or plastic (thermal resistant)
Glove thickness: 0.7 mm or thicker
Break through time: > 240 minutes
Other protective equipment: Flame retardant antistatic protective clothing may be required if used in areas where flammables are processed.
Respiratory protection: A properly fitted air purifying respirator or air supply respirator should be worn if a risk assessment indicates that respiratory protection is necessary. Respirator selection must be based upon known or measured levels of exposure.
Hygiene measures: Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Discard contaminated clothing or wash thoroughly before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.
Exposure Limit Not Available

                                                                                                     

                                                     Gloves                                Suit                          

Physical Form Solid pellets, chubs   
Appearance White (off-white, clear or pigmented)
Odour Odourless or Faint Odour
Odor Threshold Not available
pH Not applicable
Melting Point 80-120 °C
Boiling Point 228 °C
Flash Point  >340 °C estimated
Evaporation Rate Not Applicable
Flammability (solid, gas) No Data Available
Explosive limits No Data Available
Vapour pressure No Data Available
Vapour Density No Data Available
Specific Gravity  0.92-.95
Partition coefficient No data available
Explosive properties None
Water Solubility Insoluble
Solvent Solubility Slightly soluble in hydrocarbon solvents
Ignition temperature No information available.
Viscocity Not Applicable
Volatillity 0%
Reactivity                                             No hazardous reactivity.
Stability The product is chemically stable under standard ambient conditions (room temperature).
Possibility of hazardous reactions Does not react at normal processing temperatures.
Conditions to avoid Avoid dust-air mixtures, static generation. Avoid contact with incompatible materials
Incompatible materials Avoid strong oxidizing materials
Hazardous Decomposition Thermal decomposition will yield oxides of carbon and/or acetic acid and vinyl acetate.
Rout  Of Entry                                                             Inhalation. Ingestion.
Acute oral toxicity LD50 rat: Non toxic
Dermal LD50 rabbit: No skin irritation
Acute inhalation toxicity:

No data available             

Skin irritation: Non irritating
Eye irritation (rabbit): No eye irritation
Sensitization (guinea pig): No data available
Genotoxicity and Reproductive Effects: No data available
Ames test: No data available
Specific target organ toxicity - single exposure: No data available.
Specific target organ toxicity - repeated exposure: No data available.
Aspiration hazard: No information available No information available
Toxicity in  fish   LC50:                                 No data available
Toxicity to daphnia and other aquatic invertebrates: No data available
Toxicity to algae: No data available
Persistence and degradability: No data available
Bio accumulative potential Bioaccumulation not expected
Other adverse effects:

No additional environmental adverse effects are known.

Results of PBT and vPvB assessment Assessment not available.
Additional ecological information Do not allow product to enter surface waters, wastewater or soil.

 

Waste treatment Method The generation of waste should be avoided or minimized wherever possible. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe way. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Avoid dispersal of spilled material and  runoff and contact with soil, waterways, drains and sewers.

The transport regulations are cited according to international and/or harmonized transport regulations. Possible national deviations and country
specific requirements are not considered.
 

US DOT Information: No Classification assigned
TDG Information No Classification assigned
ADR Information No Classification assigned
RID Information No Classification assigned
IATA Information No Classification assigned
ICAO Information No Classification assigned
IMDG Information No Classification assigned
Fedral and State Regulation  This product is not listed under SARA Section 302 (40 CFR 355 Appendix A), SARA Section 311/312 (40 CFR 370.21), SARA Section 313 (40 CFR 372.65), CERCLA (40 CFR 302.4), TSCA 12(b), or require an OSHA process safety plan.
Other Regulation SARA Section 311/312 (40 CFR 370 Subparts B and C)
Acute Health: No Chronic Health: No Fire: No Pressure: No Reactive: No
U.S. State Regulations
 
This product is not listed on the state lists from CA, MA, MN, NJ or PA. Not listed under California Proposition 65.
Note: residual vinyl acetate is a listed material.
GHS Classifications                    Australia GHS Classifications: No published information available.
European Union GHS Classifications: No published information available.
Indonesia GHS Classifications: No published information available.
Japan GHS Classifications: No published information available.
Korea GHS Classifications (SV): No published information available.
New Zealand GHS Classifications: No published information available.
South Africa GHS Classifications: No published information available.
Taiwan GHS Classifications: No published information available.

  

Other Information

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  weassume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Ethylene Vinyl Acetate copolymer EVA EXPORTER, Supplier in UAE Middle East, Sharjah, Dubai, Ajman, Abudhabi, Fujairah, Muscat BARKA Oman, India Mumbai, Kolkata, Chennai, Vizag, Gandhidham, CANADA

Our stock points and branches