Ethylene Vinyl Acetate copolymer
- Part number
- RXSOL-96-9603-025
- Category
- Leather Chem
- Brand
- RXSOL
Overview
Ethylene vinyl acetate (EVA) copolymers are used in extrusion film processes for applications including packaging, surface protection and greenhouse covers, and in photovoltaic cell encapsulation. EVA copolymers are used in molded caps and seals, footwear and car interiors. They are the base polymer in many adhesive resin formulations and in wire and electrical cables compounding. For the hot-melt adhesive needed to hold pages and covers together in bookbinding applications, low to medium MI and high VA grades are used to maximize cohesive strength and flexibility.RXSOL EVA is an ethylene vinyl acetate copolymer with 18% VA.
Technical specifications
| Properties | Typical Value | Unit |
Test Method |
| Melt Index (190°C / 2.16 kg) | 2.5 | g/10 min | ASTM D1238 |
| Vinyl Acetate Content | 18 | wt% | ASTM D5594 |
| Density | 0.935 | g/cm3 | ASTM D1505 |
| Vicat Softening Point | 64 | °C |
ASTM D1525 |
| Melting Point | 87 | °C | ASTM D3418 |
| Tensile Strength at Yield | 5.2 | MPa | ASTM D638 |
| Tensile Strength at Break | 11 | MPa | ASTM D638 |
| Elongation at Yield | 260 | % | ASTM D638 |
| Elongation at Break | >800 | % |
ASTM D638 |
| Flexural Modulus | 60 | MPa |
ASTM D790 |
| Hardness Shore A | 76 |
ASTM D2240 |
|
| Hardness Shore D | 36 | ASTM D2240 |
Applications
RXSOL EVA can be used for blown or cast monolayer and coextruded films, or blended with other resins. Other grades can be used for molded or extruded liner seals inside plastic and metal bottle caps.
- Adhesive Lamination
- Barrier Food Packing
- Coextrusion Coating
- Compouding
- Document Plastification
- Extrusion Coating
Characteristics and notes
Benefit ::
- Low seal initiation temperature for fast packaging speeds
- Low shrink temperature
- Greater adhesion than polyethylene (PE) to a variety of substrates/layers including polyolefins, PVS, PS and PET
- Softer and clearer than PE
- Enhanced flexibility
- Increased impact strength
- Improved puncture resistance
- Excellent flex crack resistance
- Excellent flow and caulking in seal area
- Good bondage to PVdC in coextrusion processe
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | Ethylene Vinyl Acetate Copolymer |
| Part Number | RXSOL-96-9603-025 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Hazira, Mumbai, Chennai, Vizag, Kolkata , UAE & Oman
| Phone | +91 22 20871200 / 2087 1300 / 2087 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com | |
| Website | www.rxmarine.com |
| Name of Substance | Cas Number | EC Number | Wight % |
| Ethylene Vinyl Acetate Copolymer | 24937-78-8 | ------- | 100% |
| Signal Word | None |
| Hazard Statements | Not classified as dangerous for supply/use. The preparation does not meet the criteria for classification in accordance with Directive 1999/45/EC and Directive 1272/2008/EC. |
| Precautionary statements prevention | May form combustible dust-air mixtures. |
| Precautionary statements - response |
Avoid skin contact. Avoid inhalation of hot resin fumes and vapors. |
| Eye Contact |
The product is an inert solid. Treat as for any foreign object in eye. Check for and remove any contact lenses. Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical attention immediately if eyes are irritated. |
| Skin Contact | First aid is normally not required. For contact with hot products, immediately flush skin with plenty of cold water for at least 15 minutes to dissipate heat. Remove contaminated clothing and shoes. Treat as for skin burns. Get medical attention. |
| Inhalation: | For exposure to dusts, vapors and/or aerosols formed at elevated temperatures, move exposed person to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention immediately. |
| Ingestion: | Not a likely route of exposure. Wash out mouth and water. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention. |
| Extinguishing media | As appropriate for surrounding fire. Extinguish preferably with foam, carbon dioxide or dry chemical. |
| Unsuitable Extinguishing Media | Do not use water jet or waterspray. |
| Suitable extinguishing media | Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Fire Fighting Protective Equipment | A self contained breathing apparatus and suitable protective clothing should be worn in fire conditions. |
| Protective Equipment | Use personal protective equipment. |
|
Hazardous Decomposition Product(s) |
Combustion or thermal decomposition will evolve toxic and irritant vapours. |
| Advice for emergency responders | Do not take action without proper training and emergency equipment. See Section 8 for additional information. Evacuate surrounding areas. Eliminate all ignition sources including flares and all open flames. Avoid all contact with spilled material. Maintain adequate ventilation and wear appropriate respiratory protection. |
| Spillage | Sweep up, then place into a suitable container for disposal. Avoid generating dusty conditions. Provide ventilation. |
| Personal Protection | Caution - spillages may be slippery. Ensure suitable personal protection (including respiratory protection) during removal of spillages. Dust clouds are sensitive to ignition by electrostatic discharge. |
| Enviromental Precaution | Avoid dispersal of spilled material, runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). |
|
Methods and materials for containment and cleaning |
Stop spill if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, surface waters, basements or confined areas. Wash spillage into effluent treatment plant. Contain and collect spillage using appropriate personal protective equipment. Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handing chemical products or if a risk assessment indicates this is necessary. Collect and contain spillage with non-combustible, absorbent material (e.g. sand, earth, vermiculite or diatomaceous earth) and place in a container for disposal according to local regulations. Use spark-proof tools and explosion proof equipment if flammable gasses, liquids or vapors are present in the spill area. Contaminated absorbent material may pose the same hazard(s) as the spilled product. |
| Handling | Observe all label precautions. Use appropriate personal protective equipment (see section 8). Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. To avoid fire or explosion, dissipate static electricity during transfer by grounding and bonding containers and equipment before transferring material. |
| Storage |
Keep only in the original container. Keep container tightly closed. Keep in a cool, well ventilated place. Keep away from heat and direct sunlight. This product should be kept away from naked flames and other sources of ignition. Bulk storage should be in approved vessels, preferably steel that is grounded and vented Keep use containers tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination |
| Specific end uses | No other additional special end uses are anticipated. |
.
| Engineering Control | Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. |
| Personal Protectiol |
Eye/face protection: Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to product dusts, liquid splashes or mists. Goggles should be worn where eye contact is possible. Hand protection: Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is required. Glove material: cotton or plastic (thermal resistant) Glove thickness: 0.7 mm or thicker Break through time: > 240 minutes Other protective equipment: Flame retardant antistatic protective clothing may be required if used in areas where flammables are processed. Respiratory protection: A properly fitted air purifying respirator or air supply respirator should be worn if a risk assessment indicates that respiratory protection is necessary. Respirator selection must be based upon known or measured levels of exposure. |
| Hygiene measures: | Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Discard contaminated clothing or wash thoroughly before reusing. Ensure that eyewash stations and safety showers are close to the workstation location. |
| Exposure Limit | Not Available |
Gloves Suit
| Physical Form | Solid pellets, chubs |
| Appearance | White (off-white, clear or pigmented) |
| Odour | Odourless or Faint Odour |
| Odor Threshold | Not available |
| pH | Not applicable |
| Melting Point | 80-120 °C |
| Boiling Point | 228 °C |
| Flash Point | >340 °C estimated |
| Evaporation Rate | Not Applicable |
| Flammability (solid, gas) | No Data Available |
| Explosive limits | No Data Available |
| Vapour pressure | No Data Available |
| Vapour Density | No Data Available |
| Specific Gravity | 0.92-.95 |
| Partition coefficient | No data available |
| Explosive properties | None |
| Water Solubility | Insoluble |
| Solvent Solubility | Slightly soluble in hydrocarbon solvents |
| Ignition temperature | No information available. |
| Viscocity | Not Applicable |
| Volatillity | 0% |
| Reactivity | No hazardous reactivity. |
| Stability | The product is chemically stable under standard ambient conditions (room temperature). |
| Possibility of hazardous reactions | Does not react at normal processing temperatures. |
| Conditions to avoid | Avoid dust-air mixtures, static generation. Avoid contact with incompatible materials |
| Incompatible materials | Avoid strong oxidizing materials |
| Hazardous Decomposition | Thermal decomposition will yield oxides of carbon and/or acetic acid and vinyl acetate. |
| Rout Of Entry | Inhalation. Ingestion. |
| Acute oral toxicity LD50 rat: | Non toxic |
| Dermal LD50 rabbit: | No skin irritation |
| Acute inhalation toxicity: |
No data available |
| Skin irritation: | Non irritating |
| Eye irritation (rabbit): | No eye irritation |
| Sensitization (guinea pig): | No data available |
| Genotoxicity and Reproductive Effects: | No data available |
| Ames test: | No data available |
| Specific target organ toxicity - single exposure: | No data available. |
| Specific target organ toxicity - repeated exposure: | No data available. |
| Aspiration hazard: No information available | No information available |
| Toxicity in fish LC50: | No data available |
| Toxicity to daphnia and other aquatic invertebrates: | No data available |
| Toxicity to algae: | No data available |
| Persistence and degradability: | No data available |
| Bio accumulative potential | Bioaccumulation not expected |
| Other adverse effects: |
No additional environmental adverse effects are known. |
| Results of PBT and vPvB assessment | Assessment not available. |
| Additional ecological information | Do not allow product to enter surface waters, wastewater or soil. |
| Waste treatment Method | The generation of waste should be avoided or minimized wherever possible. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe way. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. |
The transport regulations are cited according to international and/or harmonized transport regulations. Possible national deviations and country
specific requirements are not considered.
| US DOT Information: | No Classification assigned |
| TDG Information | No Classification assigned |
| ADR Information | No Classification assigned |
| RID Information | No Classification assigned |
| IATA Information | No Classification assigned |
| ICAO Information | No Classification assigned |
| IMDG Information | No Classification assigned |
| Fedral and State Regulation | This product is not listed under SARA Section 302 (40 CFR 355 Appendix A), SARA Section 311/312 (40 CFR 370.21), SARA Section 313 (40 CFR 372.65), CERCLA (40 CFR 302.4), TSCA 12(b), or require an OSHA process safety plan. |
| Other Regulation |
SARA Section 311/312 (40 CFR 370 Subparts B and C) Acute Health: No Chronic Health: No Fire: No Pressure: No Reactive: No |
|
U.S. State Regulations |
This product is not listed on the state lists from CA, MA, MN, NJ or PA. Not listed under California Proposition 65. Note: residual vinyl acetate is a listed material. |
| GHS Classifications |
Australia GHS Classifications: No published information available. European Union GHS Classifications: No published information available. Indonesia GHS Classifications: No published information available. Japan GHS Classifications: No published information available. Korea GHS Classifications (SV): No published information available. New Zealand GHS Classifications: No published information available. South Africa GHS Classifications: No published information available. Taiwan GHS Classifications: No published information available. |
| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
Availability
Ethylene Vinyl Acetate copolymer EVA EXPORTER, Supplier in UAE Middle East, Sharjah, Dubai, Ajman, Abudhabi, Fujairah, Muscat BARKA Oman, India Mumbai, Kolkata, Chennai, Vizag, Gandhidham, CANADA