Buffer Cleaner
Oman Chemical is leading one Largest Supplier, Manufacture a
It is very Powerful Aluminium Cleaner
Appearence | liquid |
Colour | light red |
Odour | mild |
Melting point: | not applicable |
Flash point | not applicable |
Spontaneous ignition |
not applicable, no Danger of explosion |
This product is avilable with all our associated ship chandlers of INDIA and Middle East by product code no RXSOL-16-1028-025.
we are manufactrer of RXSOL-16-1028-025 , and supplier in kakinada, Visakhapatnam, Vizag, Mumbai, Goa, Surat, Gandhidham, Kandla, Mundra, Chennai, Ennore, Kolkata, Haldia, Pirpav, Fujairah, Dubai, Sharjah, Abu Dhabi and Gulf.
RXSOL brand Aluminium Cleaner exporter for TURKEY, Australia.
Property | Value |
---|---|
Appearance | Clear to slightly hazy amber liquid |
Odor | Mild characteristic |
pH (as supplied) | Alkaline |
Specific Gravity @ 25°C | 1.10 – 1.20 |
Solubility | Fully water soluble |
Freeze Point | Below 0°C |
Shelf Life | 12 months (sealed container) |
Parameter | Result |
---|---|
Appearance | Paly Yellow, Clear liquid |
Density | 1.01-1.1 |
Boiling Poitnt | 100 degree celcius |
Frequently Asked Questions about Boiler treatment
Answer:
A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.
Answer:
Choosing the right inhibitor depends on:
Boiler pressure and temperature
Feedwater quality (e.g., hardness, pH, oxygen content)
Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)
Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).
Answer:
The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.
Solubility (10 % Aquous Soln) | V. S. Hazy to clear solution. |
pH Value of 5% Solution | 3.5 to 4.5 |
Specific Gravity @ 25° C | 1.310 – 1.370 |
Density, lbs/gal @ 25° C | 10.9 - 11.3 |
Description | Oxygen Scavenger for Boiler |
Standard Packing | 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel |
The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.
Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.
The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.
The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation
It is used to arrest oxygen in sea water
It removes Entrapped Oxygen and thus reduces Corrosion
In Oil Drilling Chemicals
Appearance | Paly Yellow, Clear liquid |
Density | 1.01-1.1 |
Boiling Poitnt | 100 degree celcius |
Frequently Asked Questions about Boiler treatment
Answer:
A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.
Answer:
Choosing the right inhibitor depends on:
Boiler pressure and temperature
Feedwater quality (e.g., hardness, pH, oxygen content)
Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)
Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).
Answer:
The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.
This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / Color : White, viscous liquid
Our others valauable Products :
BOILER TREAT ONE SHOT
Combined Boiler Water Conditioner
A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.
HARDNESS CONTROL
Boiler Water Conditioner
Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.
ALKALINITY CONTROL
Boiler Water Conditioner
Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.
HYDRAZIDE
Oxygen Scavenger
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.
BOILER TREAT COMBI
Organic Boiler Water Treatment
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.
LIQUID COAGULANT
Oil and Sludge Conditioner
Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.
CONDENSATE CONTROL
Steam and Condensate Conditioner
Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.
COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.
EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.
Solubility (10 % Aquous Soln) | V. S. Hazy to clear solution. |
pH Value of 5% Solution | 3.5 to 4.5 |
Specific Gravity @ 25° C | 1.310 – 1.370 |
Density, lbs/gal @ 25° C | 10.9 - 11.3 |
Description | Oxygen Scavenger for Boiler |
Standard Packing | 30 Kg / 50 Kg. / 250 kg HM HDPE Barrel |
The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.
Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.
The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.
The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation
It is used to arrest oxygen in sea water
It removes Entrapped Oxygen and thus reduces Corrosion
In Oil Drilling Chemicals
Molybdate-Phosphate for Closed Circulation Machinery Cooling Corrosion inhibitor.
Appearance |
Clear Colourless to Pale Liquid |
Boiling point [oC] |
100 |
C Density [kg/m3] |
1.12 - 1.20 |
Flashpoint[oC] TCC |
NONE Vapour pressure [mm Hg] |
Pour point [oC] |
NONE Vapour density [a ir=1]: |
Auto-ignition temp [oC] | NONE |
Expl.omr. [vol%] Solubility in water [w-%]: | 100% |
pH : | Slight Alkaline |
Solubility | 100% in Distilled water |
Rel. evaporation Rate. | N/A |
Recommend Dosage ppm LEVEL | 400 to 1000 ppm |
Soluble in organic solvent: | None |
Use proper chemical protective hand gloves and Eye Goggles.
CorroSOL 50 Molybdate Corrosion Inhibitor closed cooling systems Molybdate Phosphonate is very effective in high hardness, highly alkaline scaling waters. It contains a proprietary blend of organic and polymeric sequestrants, penetrants and dispersants to minimize system fouling from contaminants such as calcium, silica, iron, sludge and organics. It also contains a unique blend of organic and actives to corrosion sites. Corrosion inhibitor closed cooling systems Molybdate Phosphonate is very effective also in low hardness, low alkalinity corrosive waters. It contains special filming ingredients to establish protective barriers against corrosion on ferrous metal surfaces. It also contains special filming ingredients to establish a protective barrier against corrosion and pitting on both yellow metal and ferrous metal surfaces.
Corrosion inhibitor closed cooling systems Molybdate Phosphonate is environmentally safe for discharge with the cooling system bleedoff. The formulation contains no heavy metals, chromates, or other pollutants requiring removal or treatment prior to discharge at normal usage rates.
Molybdate does not provide a nutrient source as do many other corrosion inhibitors. This eliminates a food source for algae and bacteria in the water system and makes control of microorganisms easier at lower microbiocide dosage rates. Corrosion inhibitor closed cooling systems Molybdate Phosphonate may be used alone as a single product for control of corrosion in systems where hardness and alkalinity does not pose a scaling problem, or in high hardness and/or high alkalinity waters where higher cycles of concentration and lower bleed rates are desired. Corrosion inhibitor closed cooling systems Molybdate Phosphonate offers superior corrosion protection for all metals typically found in cooling water systems. The blend of cathodic and anodic inhibitors provides a durable corrosion inhibitive film for maximum system protection and minimal corrosion rates.
Synergised Molybdate Corrosion Inhibitor
Appearance |
Colourless |
Odour |
Odourless |
pH |
11-12 approx |
Boiling Point / Boiling Range |
Not determined |
Melting Point/Melting Range |
N/A |
Flash Point | N/A |
Flammability | Non flammable |
Autoflammability | N/A |
Explosive Properties | N/A |
Oxidising Properties | N/A |
Vapour Pressure | Not determined |
Relative Density | 1.18 approx |
Solubility in water | Miscible |
Solubility in other solvents | Not determined |
Partition coefficient and N-octanol/water | ---------- |
Other Data |
None |
CharactersItics | Properties | |
Appearance Thermal Firmness | Clear yellow liquid 250° C | By keeping heat transfer surfaces free of scale, Ensures that the evaporator works at maximum efficiency. |
Density | In g/cm3 at 15°C: 1.1 |
Permits more efficient evaporation. |
pH (1 Vol%) | 9 |
Reduces downtime and maintenance costs. |
Compatibility | Concentrated, safe liquid, easy and economical dosing. | |
Metal | No known effect |
For use in both high pressure and vacuum evaporators |
Rubber | No known effect | The antifoaming properties ensure that distillate quality is high |
Packaging |
20 / 25 ltr |
Improves the quality of distilled water |
RXSOL-51-6001-025 is a concentrated solution of a POLYELECTROLYTE polymer and Antifoaming Agents for use in SEA WATER evaporator as a controller of scale and foam in side the evaporators. It can be used as a scale inhibitor in the feed water to EVAPORATORS producing fresh water .
A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators