Calcium Silicate Powder

Size:

Color:

Product Short Description: Used in building materials, such as some types of glass and cement (especially Portland cement), bricks and tiles for roofs, fireproof ceilings, and building boards.
Product Technical Specification:

CALCIUM SILICATE – 95 %

PARTICULARS TYPICAL REPORT
CaSiO3 as CaO + SiO2 93.80 Min
Fe2O3 + Al2O3 01.00 Max
Other Contents 01.00 Max
Loss On Ignition 04.00 Max
Brightness 85 %
Bulk Density – LOOSE 00.50
Bulk Density – TAPPED 00.85
 

 

CALCIUM SILICATE – 88 %

PARTICULARS TYPICAL REPORT
CaSiO3 as CaO + SiO2 86.00  Min
Fe2O3 + Al2O3 06.00 Max
Other Contents 01.50 Max
Loss On Ignition 07.00 Max
Brightness 65 %
Bulk Density – LOOSE 00.80
Bulk Density – TAPPED 1.40
 
Remarks:

Calcium Silicate [Calcium Metasilicate] CaO + SiO2 as under:

Chemical Composition

Calcium Silicate 84 % Min 
Colour : Off-White,  Bulk Density : 01.70 %  ,  Retention on 300 BSS # 2.5 % Max


Calcium Silicate 90  % Min , 
Colour : Off-White,  Bulk Density : 01.50 % ,  Retention on 300 BSS #  1.0 % Max,
 

Calcium Silicate 94 % Min, 
Colour : Snow White ,  Bulk Density : 0.85  % Tapped,  Retention on 300 BSS #  1.0 % Max,  

Images: Alt



Super Plasticizer FlowMaster Concrete

Size:

Color:

Product Short Description: Coating formulations with RXSOL-67-6704-020 containing polymers prevent calcium ions from being formed as LIME on concrete surface and improve the appearance and durability of coating.
Product Technical Specification:

Physical Properties:

Appearance  Colourless to pale liquid
Volumetric mass @ 250 C 1.08 ± 0.02 kg/litre  
Chloride Ion content As per BS EN : 480-10-1997* (Product contains a chemical which interferes in the procedure as per IS 9103
Workability Retention 2 hours and more Depending on Dosage


Storage
Super Plasticizer FlowMaster Concrete should be stored in dry and ventilated area at temperature above 0° C. If material is frozen please contact us. Shelf life is 1 year when stored in dry conditions between 10° C to 25° C in original unopened packages.




 

Remarks:

RXSOL-67-6704-210 is for industrial use only and should be kept out of reach of children. This is non-toxic, non-flammable and non hazardous. However, any splash on the human body should be washed out immediately with plenty of water.

STORAGE : Stable under normal conditions. Should be stored away from direct sunlight.
HANDLING : Use of gloves and safety glasses is recommended.
PACKING :

Available in 25 Ltr. 210 Ltr drums and 1000 Ltrs IBC Tanks

 
Images: Alt



Lead Monoxide

Size:

Color:

Product Short Description: Litharge is also known as Lead Oxide or Lead Monoxide. Litharge is a secondary mineral and it is a red or yellow crystalline powder
Product Technical Specification:

Chemical Formula-PbO
Molecular Weight-223.20
Color-Reddish or Yellow crystalline Powder
Gravity-9.5 – 9.7 microns
Melting Point-888 - 897oC
Synonyms-Lead Oxide, Lead Monoxide, Lead Litharge PbO

Remarks:
Images: Alt



Sulfosalicylic Acid

Size:

Color:

Product Short Description: 2-Hydroxy-5-sulfobenzoic acid
Product Technical Specification:
Sulfosalicylic Acid
2-Hydroxy-5-sulfobenzoic acid

Chemical FormulaHOC6H3(COOH)SO3H·2H2O
Formula Weight254.22
Equivalent Weight127.11 (Molar = 2 Normal)
CAS No.5965-83-3

Remarks:
Images: Alt



Patchouli Oil 30 Percent

Size:

Color:

Product Short Description: Patchouli oil is produced by steam distillation of the dried leaves of Pogostemon Cablin
Product Technical Specification:
Remarks:
Images: Alt



MembraneClean MC 33 Alkaline RO Cleaner

Size:

Color:

Product Short Description: Membrane cleaner developed to support the cleaning of iron oxides, hydroxides and acid-insoluble sulfates of calcium, barium and strontium as well as calcium fluoride
Product Technical Specification:

Physical Properties


Appearance Light Yellow
Physical State Liquid
pH 11-13
Density 1.2-1.3 gm/cm3
Boiling Point 107 deg C
Remarks:
Images: Alt



MembraneGuard MG 11 Silt Remover

Size:

Color:

Product Short Description: Remove organics, silt and other particulate deposits from polyamide, polysulfone and thin film composite membrane surfaces
Product Technical Specification:
Remarks:
Images: Alt



RO Membrane Clean LOW pH

Size:

Color:

Product Short Description: Low pH cleaner formulated to remove severe calcium carbonate scaling and moderate metal fouling and metal-organic Complexs
Product Technical Specification:

Pl. refer our Technical Bulletine and MSDS of Product.

This advanced, high strength formulation available in powder  /  liquid form 
• pH adjusted to 3.0+ 0.5
• Highly effective at ambient temperatures
• Contains no surfactants and is quickly rinsed away
• Contains organic acids, detergent builders and chelating agents

Remarks:

Safety Goggles, And Hand Gloves is compoulsery before using this product. And for more details pl. ask MSDS.  

Membrane Cleaner RXSOL- 3304  MC3 is a low pH formulation that has been designed specifically to remove metal hydroxides, calcium carbonate and other similar scales from polyamide, polysulfone and thin film, composite membrane surfaces.

Images: Alt



Scale Inhibitor Antiscalant

Size:

Color:

Product Short Description: Very power full superior product which making the film to protect the Corrosion and antiscalant in Pipe line and equipment where supplies hot and cold water.
Product Technical Specification:

Odour

Odourless

Appearance

Liquid, Clear

pH

11.5  at 100 % concentration

Boiling point

100 °C at 760 mm /Hg

Vapour pressure

not known

Freezing point

 <0 °C at 760 mm/Hg

Completely soluble in water

 

Specific gravity (water=1)

1.15 - 1.7

   
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Scale Hardness Stabilizer

Size:

Color:

Product Short Description: Seawater Treatment and dispersing agent formulated Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid.
Product Technical Specification:

 

Appearance

: Clear liquid

Specific gravity at 25 º C (77 º F)

: 1.2

Fire

: off

Freezing temperature

: -6.6 º C (20 º F)

pH

: 5-7

Stability after freeze / that

: yes

Remarks:

Did you know, how to keep system scale and corrosion free, water CLEAR and Sludge free?

RXSOL-33-5027-025 Scale Hardness Stabilizer contains Polycarboxylate Phosphate and synthetic low molecular wt polymer  to control sludge which results in the clean boiler water. USES of RXSOL-33-5027-025 control Hardness and provide tolerance of feedwater quality fluctuations.

Chemically one part of The RXSOL-33-5027-025 polymers  keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during cleaning and maintenance operation.


While Other part of Phosphate which is used in RXSOL-33-5027-025 serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.

USES of RXSOL-33-5027-025 during sea water treatment, can help and keep WATER CLEAN and CLEAR.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Scale Hardness Stabilizer

Size:

Color:

Product Short Description: Seawater Treatment and dispersing agent formulated Polyacrylate material of low molecular weight. Non-volatile used for scale inhibition in sea water treatment. The product is miscible with water in all proportions. And is clear Liquid.
Product Technical Specification:

 

Appearance

: Clear liquid

Specific gravity at 25 º C (77 º F)

: 1.2

Fire

: off

Freezing temperature

: -6.6 º C (20 º F)

pH

: 5-7

Stability after freeze / that

: yes

Remarks:

Did you know, how to keep system scale and corrosion free, water CLEAR and Sludge free?

RXSOL-33-5027-025 Scale Hardness Stabilizer contains Polycarboxylate Phosphate and synthetic low molecular wt polymer  to control sludge which results in the clean boiler water. USES of RXSOL-33-5027-025 control Hardness and provide tolerance of feedwater quality fluctuations.

Chemically one part of The RXSOL-33-5027-025 polymers  keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during cleaning and maintenance operation.


While Other part of Phosphate which is used in RXSOL-33-5027-025 serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.

USES of RXSOL-33-5027-025 during sea water treatment, can help and keep WATER CLEAN and CLEAR.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



pH Booster Morpholine Base

Size:

Color:

Product Short Description: RXSOL pH Boosters are morpholine based alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.
Product Technical Specification:

 

Properties Unit Typical Value
Form and Appearance - Clear Colorless Liquid
Odor - Characteristic
pH (neat) pH Alkaline
Solubility - Completely Soluble in Water
Remarks:

STORAGE & HANDLING

pH booster should be stored in an air tight container away from direct heat.
Always store at cool & dry place.
Handle using goggles & do not breathe in the vapours.
Wash thoroughly in case of contact. Do not swallow.

 

pH Control

Maintenance of proper pH throughout the boiler feedwater, boiler, and condensate systems is essential for corrosion control. Most low-pressure boiler system operators monitor boiler water alkalinity because it correlates very closely with pH, while most feedwater, condensate, and high-pressure boiler water requires direct monitoring of pH. Control of pH is important for the following reasons:

  • corrosion rates of metals used in boiler systems are sensitive to variations in pH
  • low pH or insufficient alkalinity can result in corrosive acidic attack
  • high pH or excess alkalinity can result in caustic gouging/cracking and foaming, with resultant carryover
  • speed of oxygen scavenging reactions is highly dependent on pH levels

The pH or alkalinity level maintained in a boiler system depends on many factors, such as sys-tem pressure, system metals, feedwater quality, and type of chemical treatment applied.

The corrosion rate of carbon steel at feedwater temperatures approaches a minimum value in the pH range of 9.2-9.6 . It is important to monitor the feedwater system for corrosion by means of iron and copper testing. For systems with sodium zeolite or hot lime softened makeup, pH adjustment may not be necessary. In systems that use deionized water makeup, small amounts of caustic soda or neutralizing amines, such as morpholine and cyclohexylamine, can be used.

In the boiler, either high or low pH increases the corrosion rates of mild steelThe pH or alkalinity that is maintained depends on the pressure, makeup water characteristics, chemical treatment, and other factors specific to the system.

The best pH for protection of copper alloys is somewhat lower than the optimum level for carbon steel. For systems that contain both metals, the condensate and feedwater pH is often maintained between 8.8 and 9.2 for corrosion protection of both metals. The optimum pH varies from system to system and depends on many factors, including the alloy used 

To elevate pH, neutralizing amines should be used instead of ammonia, which (especially in the presence of oxygen) accelerates copper alloy corrosion rates. Also, amines form protective films on copper oxide surfaces that inhibit corrosion.

Images: Alt
stock-clearance.png