RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,061 products across 71 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Cooling Water Chemical

Cooling Treat 2910

New Generation product fo use as Corrosion Inhibitor for Chiller closed systems
Part number
RXSOL-40-4090-025
Brand
RXSOL
Cooling Treat 2910

Overview

RXSOL Cool water Treat Inhibitor  is a organic liquid corrosion inhibitor with low-toxic poerty provides long-life corrosion protection for closed cooling water systems . RXSOL Cool water Treat Inhibitor  will protect all commonly used materials in engine cooling water systems, including aluminium. Cool water Treat Corrosion Inhibitor  does not contain components subject to rapid depletion. Cool water Treat Inhibitor Corrosion Inhibitor for Chiller closed systems  is stable and  biodegradable.

Technical specifications

Physical Properties
  
Density                    1.06
Packing, Type         25 Ltrs
Colour                    Colourless
Appearance            Liquid

Applications

Liquid product, easy to use. Environmentally friendly, fully organic product, low toxicity. Effective against cavitation and erosion. Superior heat transfer properties. Compatible with hoses, gaskets and seals. Compatible with glycols for frost protection. Stable product - non depleting. The product can be used for corrosion inhibition in many types of closed re-circulation system such as: - Diesel engine cooling water systems - Compressor cooling water systems - Centralised cooling systems - Hot water heating systems - Auxiliary machinery cooling systems.

Dosage and directions

Using Method : -

RXSOL Cool water Treat Inhibitor is a highly effective corrosion inhibitor for all common metals in cooling water systems.Where most traditional inhibitors react with the metal surface and form oxides that prevent further corrosion, Cool water Treat Corrosion Inhibitor  applies a thin and durable layer of protective molecules to the metal surfaces. This technology prevents the continuous build-up of insulating layers on heat transfer surfaces.

For new builds, RXSOL  recommends cleaning of the water system before commercing service. The system will always contain small amounts of oil and iron oxides, and this can be easly removed in 1 time with RXSOL Commissioning Cleaner. If the system is corroded or is more heavily contaminated use RXSOL Degreaser HD. Rxsol Safe Acid  for removal of metal oxides or scale is recommended.
For systems previously treated with other products, Our R&D team recommend to drain and flush the system before refilling with distilled water and Cool water Treat Corrosion Inhibitor . The system should be clean and free from scale and corrosion products when starting the treatment.
The use of antifreeze is sometimes required if the vessel is to be laid up in cold areas, Cool water Treat Corrosion Inhibitor  can be used in conjunction with glycols for frost protection. If used in conjunction with glycols, It is recommended to increase the product concentration to 8%.

Dosing method
Cool water Treat Corrosion Inhibitor  should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured.
Dosage and control
Cool water Treat Inhibitor  should always be present in a concentration of 5% or higher in the system. It is good practice to start with initial dose for an untreated system of 60 litres of Cool water Treat Inhibitor  / ton. 5% will provide sufficient protection of the system for a period of two to five years under normal conditions provided. To prevent residual falling below minimum level due to loss of cooling water, To get optimum result recommend to maintain a level of 6% Cool water Treat Inhibitor  in the cooling system.
The engine manufacturer's recommendations for water quality should always be complied with. Cool water Treat Corrosion Inhibitor  provides good protection even with contamination of the system by i.e. inorganc salts. Maintain Chloride levels and other contaminants at a minimum level. Most engine manufacturers recommend a maximum of 50 ppm Chlorides.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name  Cool water Treat Inhibitor Cool water Treat Corrosion Inhibitor 2910 (Corrosion Inhibitor)
Product Code RXSOL-40-4090-025

 Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

 

Compoent CAS % by wt. Exposure guidlines
Sodium Nitrite 7623-00-0 30-40 NE
Sodium Hydroxide 1310-73-2 <10 <2 mg/m3
Water Softener- Polymer Blend Proprietory 15-20 NE

 Environmental Hazards :

This preparation is as dangerous. Toxic to aquatic organisms

Physical/ Chemical Hazards :

  • If product is allowed to dry, the sodium is an oxidizing agent
  • Can initiate the combustioj of other agent
  • Contact acids libertes Toxic gases
Skin Remove contaminated clothing. Wash skin throughly with soap water
Eyes Flus eyes liberally with low pressure water for least 15 minutes, lift the eyelids occasionally to aid removed od material
Inhalation Immeditely move personnel to area of fresh air. For respitory distress,give air.Oxygen or administer CPR (Cardiopulmonary Resucition),if necessary. Obtain medical attention immedlitely.
Ingestion Rinse mouth with water. Do not induce vomiting unless by medical personnel. Obtain medical attention
Fire extingishing media Not expected to burn use extingushing media appropriate for surounding fore
Basic fire fighting procedure Water apray is recommended to cool fire exposed surfaces and to protect personel. Wear self contained breathing appratus
Unusual fire & explosion hazards Oxides of Nitrogen oxides of Carbon (under fire conditions). If product is allowed to dry, the sodium nitrite is an oxidesing agent and intiate the combustion of other materials
Personnel precautions Use personnel protective equipment,breathing apparatus required only in fire sitution
Evironmental precautions Do not flush into surface area or sanitary sewer system,use aborent like sand or absorbet material saw dust, waste cotton etc. to contain spill prevent material from entering and waterways
Eye protection Water chemical splash gogles and face shield(ANSI Z87.1 or approved equivalent)
Skin & body protection Where splashing is possible, fully chemical restant protectiove light weight clothing(chemical resitant apron)and safety boots are required
Respiratory preection An approved respiator must be worn,if the occupational exposure limit is likely to be exceeded, filter type A/P-3
Appearance Form Liquid at 25 0C
Density 1.02-1.18
Solubility completely solule in water
Odour odourless
Boiling point >100 0C
pH Alkaline
Stability/ incompatibility State at ambient temperture
Materials to avoid Avoid contact chemical, acids,organic materials, and reducing agents
Hazardus de-compositiin product Oxides of Nitrogen, Oxides of Carbon etc.

Acute toxicity : the following results are for the active

Acute lethality Valuues : Sodium Nitric oral (rat) LD 50-85 mg/kg

No data avalible on the product

ADDITIONAL ECOLIGICAL DATA - Nitrite is to fish

 

Waste disposal : Dispose according to lical, stae federal requirment. THis is not suitable for disposal by either landfill or muncipal sewer, dreins nature or reiver

Hazard Label : Corrosive liquid,Toxic n.o.c. ADR NO :86
UN number : 2922
Class : 8
Packing group :III
EMS : F-A-S-B 

 Classification and Labeling According to ECC Directves
Hazard Symbol : TOXIC
Hazard symbol : Dangerous for the environment
Governing Directive : Dangerous Substances Directive 67/548/Eec, As Modified

Label Name Corrosive liquid,Toxic
Nature of special Risk

R25 Toxic swallwed.

R34 Causes burns.

R50 Toxic to aquatic orgnisms

Safety Advice

S36/37/38 Wear suitable protective clothing and eye/face protection.

S26 In cse of contact with eyes rinse immeditely with plenty of water

Recommeded use : Corrosion inhibitor for the closed cooling system

Notice : This information related specifically ti the peoduct designated and may not vaild product when used in combination with any other material or product process. The information is to the bewst of our knowledge and belief, acrate and relible as of the date compiled. Howevwe no repersentaion warreanty or guarantee is made as to its accrancy, reliablity or completencess.It emplyees or customers in accordance fedreal state or local hazrds communications requirement. We do ot accept resonsible for any loss damage which may from use of this information.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Cool water Treat Inhibitor exporter, manufacturer and supplier in Mumbai, Navi Mumbai, Surat Hazira, Gandhidham Kandla, Chennai - Ennore, Vizag Visakhapatnam Gangavaram, Kolkata Haldia Paradip, Fujairah, Dubai, Surat, Abudhabi, Sharjah Middle East, Muscat Oman, Canada

Our stock points and branches