RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,082 products across 97 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Test Kit For Water

Hardness Titration Solution - I

Hardness Reagent Solution
Part number
RXSOL-62-5531-001
Brand
RXSOL
Hardness Titration Solution - I

Overview

Titration sol’n., (EDTA), 40 mg/L, 2 EPM, 8 oz

Applications

EDTA solution is added to the ( indicator mixed with testing water ) solution and reacts with the free metal ions (those not bonded to the indicator). Since the metal-EDTA complexes are colorless, the solution still appears red.

EDTA continues to be added. After all the free metal ions are bound to the EDTA, the EDTA displaces the indicator, complexing the remaining metal ions until all metal ions are bound to EDTA. The red metal-indicator complex is no longer present and the indicator is free. The indicator is a weak acid and its color is dependent on how it is protonated:

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-62-5531-001
Product Type Hardness Titration Solution - I

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA 

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

    

 SARA 313           Component  CAS Number  Percent  Comp. Dimension
 
Exposure
 Limits
 
  Ethylenedinitrilotetra - acetic Acid, Disodium Salt  CAS# 6381-92-6  0.1 -0.5%  W/V None
established
 
 Water, Deionized ASTM Type II   CAS# 7732- 18-5   98.05% V/V None
  established
 

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

Emergency Overview:Caution! May Cause Irritation to Skin and Eyes.

Inhalation:No Adverse Health Effects Expected from Inhalation.

Ingestion:Substance has Low Toxicity by Ingestion. Large Amounts May Cause Gastrointestinal Upset due to Osmotic Imbalance Caused by its ability to Sequester Metal Ions.

Skin:May Cause Irritation with Redness and Pain.

Eye Contact:May Cause Irritation, Redness and Pain.

Chronic Exposure:No Information Found.

May be harmful if swallowed. May cause irritation. Avoid breathing vapors, or dusts. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling.

FIRST AID: SKIN: Wash exposed area with soap and water. If irritation persists, seek medical attention.

EYES: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid. INHALATION: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen

INGESTION: Give several glasses of water. Vomiting may occur, but it is not necessary to induce.

Fire Extinguisher Type

 Any means suitable for extinguishing
 

Fire / Explosion Hazards  None
 
 Fire Fighting Procedure  Wear self-contained breathing apparatus and protective
clothing to prevent contact with skin and clothing.

Absorb spill with inert material, then place in a chemical waste container. Dispose of in a manner consistent with federal, local law.

Ventilate Area of Leak or Spill. Wear Appropriate Personal Protective Equipment as Specified in Section 8. Contain and Recover Liquid when Possible. Collect Liquid in an Appropriate Container or Absorb with an Inert Material (Vermiculite, Dry Sand, Earth), and Place in a Chemical Waste Container. Do Not Use Combustible Materials, such as Saw Dust. Do Not Flush to Sewer

Store in a cool dry place. This Material is not considered hazardous. Handle using safe laboratory practices.

Respiratory Protection

 None required

Ventilation
 
Local
 
OTHER Mechanical
 
Protective Gloves Gloves to prevent exposure 
EYE PROTECTION

Safety Glasses w/Side Shields
 

Other Protective Equipment  Use safe laboratory handling
procedures.
BOILING POINT   ~100°C (212°F)
VAPOR  PRESSURE   Information not available
MELTING POINT    ~0°C (32° F)
VAPOR DENSITY     Information not available
EVAPORATION RATE   1
Appearance /Odors

 Clear, colorless, odorless liquid

Flash Point   Not applicable
 
Specific Gravity    ~1.0       
Percent Volatile by  >99
Evaporation Standard  Water =1
Auto Ignition Temp

Not applicable
 

Lower Flamm. Limit in Air                                                               Not applicable
Upper Flamm. Limit in Air  Not applicable
Solubility in Water Soluble

   

STABILITY

Stable

CONDITIONS TO AVOID

 Avoid contact with incompatible materials.
 

Materials to Avoid

Concentrated Acids and Bases, Water reactive materials.
 

Hazardous Decomposition Products:

Carbon monoxide, nitrogen oxides, ammonia
 

Hazardous polymerization

Will Not Occur
 
Conditions to Avoid  None known

Carcinogenic References: NTP Carcinogen - Known: No, IARC Category -None

 No Information Found.

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing, use or contamination of this product may change
the waste management options. State and local disposal regulations may differ from federal
disposal regulations. Dispose of container and unused contents in accordance with federal, state and local requirements.

DOT Classification: Not Regulated

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

Chemical Inventory Status –
Part 1:Ingrdient
EDTA Disodium Salt (139-33-3)
TSCA Yes
EC Yes
Japan YES
Australia Yes

Chemical Inventory Status –
Part 2:Ingredient
EDTA Disodium Salt (139-33-3)
Korea Yes
DSL Yes
NDSL No
Phil. Yes

Federal, State & International Regulations –
Part 1: Ingredient.
EDTA Disodium Salt (139-33-3)
RQ NO
TPQ NO
List NO
Chemical Catg No

Federal, State & International Regulations –
Part 2:Ingredient
EDTA Disodium Salt (139-33-3)
CERCLA NO
261.33 No
8(d) No

Chemical Weapons Convention:No
TSCA 12 (b):No
CDTA:Yes Mixture/Liquid)
SARA 311/312: Acute: NO
Chronic: NO
Fire: No
Pressure: No
Reactivity: No
Australian Hazchem Code: None
Poison Schedule: None allocated

Conditions aggravated/target organs: Persons with preexisting skin, eye and respiratory disorders may be more susceptible. Acute: Possible skin and eye irritation. Chronic: None known.


                                                Flammability
Health                                                                                              Reactivity

Revisions
 
NFPA
 
7/29/2010

0.1 updated msds to 16 section from 10
 

  0

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
 

Request the signed SDS as PDF

Availability

Hardness Titration Solution - I manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Hardness Titration Solution - I at a competitive price from us. We have ready stock of Hardness Titration Solution - I in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches