RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,087 products across 101 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Test Kit For Water

Palladium Chloride Passivation Test Kit

During test on passivated stainless steel, A black spot will appear when the surface has not been passivated correctly. Various qualities of passivation will give graduations of grey shades, ranging from light (acceptable) to dark (unacceptable)
Part number
RXSOL-62-5522-025
Brand
RXSOL
Palladium Chloride Passivation Test Kit

Overview

The reagent keeps colour on good passivated stainless steel. A black spot will appear when the surface has not been passivated correctly. Various qualities of passivation will give graduations of grey shades, ranging from light (acceptable) to dark (unacceptable).

Also refer this link ::: Ferroxyl Test Kit for free IRON passivation  ( http://rxmarine.com/Ferroxyl-Test-Kit-for-free-IRON ) 

                                 Passivity Test Kit for PASSIVATION  ( http://rxmarine.com/Passive-Film-Testing )

Applications

The RXSOL Passivation Test Kit is an easy and economical test kit to determine the Passiveness of austenitic stainless steel. Stainless steel is protected from corrosion by a thin layer that consists mainly of chromium oxide. Oxygen from the atmosphere is normally able to form and maintain this passive layer. Contamination, surface defects and imperfections disturb the formation and repair of the chromium oxide layer and reduce the resistance to severe or local corrosion. Therefore it is very important to test if your stainless steel is still passive to prevent corrosion and damage.

The measure of passivation of stainless steel can be determined with a palladium chloride reagent. The reagent keeps colour on good passivated stainless steel. A black spot will appear when the surface has not been passivated correctly. Various qualities of passivation will give graduations of grey shades, ranging from light (acceptable) to dark (unacceptable).

 

Palladium Test
There is no or slight colour change on well passivated stainless steel after 3 minutes wetting with palladium chloride reagent. If after rinsing a gray spot appears, the metal is partially passivated. A black spot will arise when the surface has not been passivated correctly. The palladium chloride reagent is corrosive for stainless steel, therefore it is very important to rinse carefully.

Dosage and directions

Palladium chloride test for active surfaces:

Passive steel does not liberate Hydrogen form Sulphuric acid. Palladium can absorb 900 times its own volume of Hydrogen by Adsorbsion and Occlusion. Hydrogen gas reduces Palladium Chloride PdCl2 easily to form black Palladium metal and Hydrogen Chloride.

H2 + PdCl2 = Pd + 2 HCl

This is the reason that Sulphuric acid or HCl  must be mixed with palladium chloride if the black precipitate of metal must be seen by the naked eye. Passive SS does not liberate hydrogen. Palladium Chloride results can be tested using a mass spectrometer too.

Rinse PdCl2 with DI water from a squirter as the black spot is active.
If free iron ( not oxidised iron ) is present on the SS surface the iron is oxidised by Palladium Chloride ( acid reagent solution ) to iron oxide.

4PdCl2 + 4 H2O + 3 Fe = 4 Pd + 8 HCl + Fe304

Palladium chloride comes in a small bottle with a dropper. The contact time should be 3 min minimum. The shelf life is one year if you keep it in the fridge in a coloured bottle.

we are also  supplying  it. Palladium chloride crystals or deliquiscent powder is soluble in water or alcohol.

Characteristics and notes

The RXSOL Passivation Test Kit contains:

·         Reagent TK

·         Demineralized Water (0.5 ltr)

·         Squeeze Bottle (500 ml)

·         Latex Gloves (10 pcs)

·         Non woven cleaning pads (5 pcs)

·         Instruction Manual

dimensions: 16 x 18 x 20

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-62-5522-025
Product Type Palladium Chloride Passivation Test Kit

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com
Name    CAS # composition
Palladium chloride 7647-10-1      formulated


Skin Causes skin irritation. May affect metabolism if absorbed through skin.
Eyes Causes eye irritation. May cause chemical conjunctivitis.
Ingestion May cause gastrointestinal tract irritation with nausea, vomiting and diarrhea. May affect blood, immumological system, and metabolsim
Inhalation Causes respiratory tract and mucous membrane irritation.

Eye Contact

Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention.


Skin Contact

Wash with soap and water. Cover the irritated skin with an emollient. Get medical attention if irritation develops. Cold water may be used.

Serious Skin Contact

Not available.

Inhalation

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention
Serious Inhalation  Not available.
Ingestion Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention if symptoms appear.
Serious Ingestion Not available.
Flammability of the Product Non-flammable.
Auto-Ignition Temperature Not applicable.
Flash Points Not applicable.
Flammable Limits Not applicable.
Products of Combustion Not available.
Fire Hazards in Presence of Various Substances Not applicable.
Explosion Hazards in Presence of Various Substances Risks of explosion of the product in presence of mechanical impact: Not available. Risks of explosion of the product in presence of static discharge: Not available.
Fire Fighting Media and Instructions Not applicable.
Special Remarks on Fire Hazards Not available.
Special Remarks on Explosion Hazards Not available.

Small Spill

Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to local and regional authority requirements.
Large Spill Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate through the sanitary system.

Precautions

Do not ingest. Do not breathe dust. Avoid contact with eyes. Wear suitable protective clothing. In case of insufficient ventilation, wear suitable respiratory equipment. If ingested, seek medical advice immediately and show the container or the label. Keep away from incompatibles such as metals, acids.

Storage Keep container tightly closed. Keep container in a cool, well-ventilated area. Do not store above 24°C (75.2°F).

Engineering Controls

Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.

Personal Protection Splash goggles. Lab coat. Dust respirator. Be sure to use an approved/certified respirator or equivalent. Gloves.
Personal Protection in Case of a Large Spill Splash goggles. Full suit. Dust respirator. Boots. Gloves. A self contained breathing apparatus should be used to avoid inhalation of the product. Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling this product.
Exposure Limits Not available.
Physical state and appearance Liquid.
Odor Not available.
Taste Not available.
Molecular Weight 177.3 g/mole
Color Red-Brown. (Dark.)
pH (1% soln/water) Not available.
Boiling Point Not available.
Melting Point 679°C (1254.2°F)
Critical Temperature Not available.
Vapor Pressure Not applicable.
Vapor Density Not available..
Volatility Not available.
Odor Threshold Not available.
Water/Oil Dist. Coeff. Not available.
Ionicity (in Water) Not available.
Dispersion Properties See solubility in water, acetone.
Solubility Soluble in cold water, acetone, hydrobromic acid.

STABILITY

The product is stable.

Instability Temperature

Not available.

Conditions of Instability

Excess heat, moisture, incompatible materials

Incompatibility with various substances

Reactive with metals, acids.

Corrosivity

Non-corrosive in presence of glass.
Special Remarks on Reactivity Incompatible with organic solvents, acids, NH3, Zn, strong oxidizing agents, aluminum, magnesium, nitrates, thiocyanates
Special Remarks on Corrosivity Not available.
Polymerization Will not occur.
Special Remarks on Chronic Effects on Humans May cause adverse reproductive effects and cancer based on animal data. May affect genetic material
Special Remarks on other Toxic Effects on Humans:  
Acute Potential Health Effects:  
Skin Causes skin irritation. May affect metabolism if absorbed through skin.
Eyes Causes eye irritation. May cause chemical conjunctivitis.
Ingestion May cause gastrointestinal tract irritation with nausea, vomiting and diarrhea. May affect blood, immumological system, and metabolsim
Inhalation Causes respiratory tract and mucous membrane irritation.

Ecotoxicity

Not available.

Products of Biodegradation Possibly hazardous short term degradation products are not likely. However, long term degradation products may arise.
Toxicity of the Products of Biodegradation The product itself and its products of degradation are not toxic.
Special Remarks on the Products of Biodegradation Not available.

Waste Disposal

Waste must be disposed of in accordance with federal, state and local environmental control regulations.

 NA

 NA

The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall rxmarine be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if rxmarine has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

Palladium Chloride Passivation Test Kit manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Palladium Chloride Passivation Test Kit at a competitive price from us. We have ready stock of Palladium Chloride Passivation Test Kit in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches