Passivity Test Kit for PASSIVATION
- Part number
- RXSOL-62-5529-001
- Category
- Test Kit For Water
- Brand
- RXSOL
Overview
This kit verifies if the surface is passive and if it will resist oxidation as requested by steel specifications for AISI 300 and 400. It can also be used to quickly separate Series 400 from Carbon steel.
This test will give a red/pink result when in contact with Iron. The chemicals used in these tests are not hazardous. But the surface should be carefully rinsed after the test.
Also refer this link ::: Palladium Chloride Passivation Test Kit ( http://rxmarine.com/passivation-test-kit-0 )
Ferroxyl Test Kit for free IRON passivation ( http://rxmarine.com/Ferroxyl-Test-Kit-for-free-IRON )
Applications
Apply 1-2 drops of Reagent RXSOL TK-11 to the surface to be inspected and let it react for at least 1 minute. Absorb the drop with the filter paper (supplied) and add 1 drop of Reagent RXSOL TK-12.
The paper will remain white if the surface is passive or if the piece is Stainless steel 400 Series. If the paper changes colour to pink it means that the surface is not, more or less, passive. The more pink, the less passive. An intense red colour means that the piece is Carbon steel
RXSOL TK-11
RXSOL TK-12
Safety and SDS
Read the safety data sheet before handling. Wear suitable gloves and eye protection.
View safety data sheet
| Product Name | RXSOL-62-5529-001 |
| Product Type | Passivity Test Kit for PASSIVATION |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Fujairah, Muscat
| Phone | +91 22 27815541 / 42 / 43 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| rxsolchemicals@gmail.com |
| Name | CAS # | composition |
| Potasssium Ferrocyanide Formulation | 13943-58-3 | Formulated |
| Skin | Causes skin irritation. May affect metabolism if absorbed through skin. |
| Eyes | Causes eye irritation. May cause chemical conjunctivitis. |
| Ingestion | May cause gastrointestinal tract irritation with nausea, vomiting and diarrhea. May affect blood, immumological system, and metabolsim |
| Inhalation | Causes respiratory tract and mucous membrane irritation. |
|
Eye Contact |
Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention. |
|
|
Wash with soap and water. Cover the irritated skin with an emollient. Get medical attention if irritation develops. Cold water may be used. |
|
Serious Skin Contact |
Not available. |
|
Inhalation |
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention |
| Serious Inhalation | Not available. |
| Ingestion | Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Loosen tight clothing such as a collar, tie, belt or waistband. Get medical attention if symptoms appear. |
| Serious Ingestion | Not available. |
| Flammability of the Product | Non-flammable. |
| Auto-Ignition Temperature | Not applicable. |
| Flash Points | Not applicable. |
| Flammable Limits | Not applicable. |
| Products of Combustion | Not available. |
| Fire Hazards in Presence of Various Substances | Not applicable. |
| Explosion Hazards in Presence of Various Substances | Risks of explosion of the product in presence of mechanical impact: Not available. Risks of explosion of the product in presence of static discharge: Not available. |
| Fire Fighting Media and Instructions | Not applicable. |
| Special Remarks on Fire Hazards | Not available. |
| Special Remarks on Explosion Hazards | Not available. |
|
Small Spill |
Use appropriate tools to put the spilled solid in a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose of according to local and regional authority requirements. |
| Large Spill | Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate through the sanitary system. |
|
Precautions |
Do not ingest. Do not breathe dust. Avoid contact with eyes. Wear suitable protective clothing. In case of insufficient ventilation, wear suitable respiratory equipment. If ingested, seek medical advice immediately and show the container or the label. Keep away from incompatibles such as metals, acids. |
| Storage | Keep container tightly closed. Keep container in a cool, well-ventilated area. Do not store above 24°C (75.2°F). |
|
Engineering Controls |
Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit. |
| Personal Protection | Splash goggles. Lab coat. Dust respirator. Be sure to use an approved/certified respirator or equivalent. Gloves. |
| Personal Protection in Case of a Large Spill | Splash goggles. Full suit. Dust respirator. Boots. Gloves. A self contained breathing apparatus should be used to avoid inhalation of the product. Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling this product. |
| Exposure Limits | Not available. |
| Physical state and appearance | Liquid. |
| Odor | Not available. |
| Taste | Not available. |
| Molecular Weight | 177.3 g/mole |
| Color | Red-Brown. (Dark.) |
| pH (1% soln/water) | Not available. |
| Boiling Point | Not available. |
| Melting Point | 679°C (1254.2°F) |
| Critical Temperature | Not available. |
| Vapor Pressure | Not applicable. |
| Vapor Density | Not available.. |
| Volatility | Not available. |
| Odor Threshold | Not available. |
| Water/Oil Dist. Coeff. | Not available. |
| Ionicity (in Water) | Not available. |
| Dispersion Properties | See solubility in water, acetone. |
| Solubility | Soluble in cold water, acetone, hydrobromic acid. |
|
STABILITY |
The product is stable. |
|
Instability Temperature |
Not available. |
|
Conditions of Instability |
Excess heat, moisture, incompatible materials |
|
Incompatibility with various substances |
Reactive with metals, acids. |
|
Corrosivity |
Non-corrosive in presence of glass. |
| Special Remarks on Reactivity | Incompatible with organic solvents, acids, NH3, Zn, strong oxidizing agents, aluminum, magnesium, nitrates, thiocyanates |
| Special Remarks on Corrosivity | Not available. |
| Polymerization | Will not occur. |
| Special Remarks on Chronic Effects on Humans | May cause adverse reproductive effects and cancer based on animal data. May affect genetic material |
| Special Remarks on other Toxic Effects on Humans: | |
| Acute Potential Health Effects: | |
| Skin | Causes skin irritation. May affect metabolism if absorbed through skin. |
| Eyes | Causes eye irritation. May cause chemical conjunctivitis. |
| Ingestion | May cause gastrointestinal tract irritation with nausea, vomiting and diarrhea. May affect blood, immumological system, and metabolsim |
| Inhalation | Causes respiratory tract and mucous membrane irritation. |
|
Ecotoxicity |
Not available. |
| Products of Biodegradation | Possibly hazardous short term degradation products are not likely. However, long term degradation products may arise. |
| Toxicity of the Products of Biodegradation | The product itself and its products of degradation are not toxic. |
| Special Remarks on the Products of Biodegradation | Not available. |
|
Waste Disposal |
Waste must be disposed of in accordance with federal, state and local environmental control regulations. |
NA
NA
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall rxmarine be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if rxmarine has been advised of the possibility of such damages.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
Availability
Passivity Test Kit for PASSIVATION manufacturer and supplier in Chennai, Mumbai, Kandla Gandhidham Surat, Visakhapatnam, Kolkata, Haldia, Paradip Fujairah, Sharjah, Abudhabi, Ajman, Muscat Barka Oman