RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,116 products across 118 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Cooling Water Chemical

ROCCOR NB RXSOL With Indicator

Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets.
Part number
RXSOL-40-4034-210
Generic name
ROCCOR NB RXSOL Colour Indicator
Active matter
68-75
Brand
RXSOL
Corrosion Inhibitor

Overview

Corrosion Inhibitor for Cooling Water Systems  having  unique formulation with highly concentrated liquid cooling water treatment compound with indicator, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate. 

Technical specifications

ROCCOR NB cooling water treatment chemical is Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.

Applications

Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will

suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling

efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide
 

Dosage and directions

Refer to technical datasheet.

GENERAL RECOMMENDATION : 

Nitrite (as PPM NO2) 0  100-200 300-600 700-900 1100-1300   
RXSOL-40-4033-025 / 1000L 13.0  11.3 8-10 5-7   1.5-3.5

NOTE ::: --   If nitrite level becomes 1440-2400 then doses should be ZERO.

Characteristics and notes

Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name :  RXSOL-40-4034-025
Product Type : ROCCOR NB RXSOL With Indicator

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : rxsolchemicals@gmail.com
Chemica Name Concentration CAS Number EC Number R Phrases* Symbols
 Sodium nitrite 10-30  7632-00-0  231-555-9 8, 25, 50   O,N
Borax 1-5 1303-96-4 215-540-4 62,63 Xn 
Phenophthalein 0.1-.02 77-09-8 201-004-7 NA  

*See Section 16

Odour Odourless
Appearance Pink Liquid, soluble in water
Contact with eyes May cause pain
Contact with skin In cases of severe exposure, severe irritation may develop
Inhalation Vapours or aerosols may cause irritation of eyes, nose and respiratory tract
Ingestion Toxic if swallowed (R25)
Contact with skin Remove contaminated clothing immediately and drench affected skin with plenty of water
Contaminated clothing should be laundered before reuse When in doubt or symptoms persist, seek medical attention
Contact with eyes If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes
Irrigate eyes thoroughly whilst lifting eyelids Obtain immediate medical attention
Ingestion Never make an unconscious person vomit or drink fluids Give water or milk to drink Induce vomiting (only if patient is conscious) Obtain immediate medical attention
Inhalation Inhalation is unlikely to occur Remove patient to fresh air When in doubt or symptoms persist, seek medical attention
General In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)

-  Nitrogen oxides may be formed
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
-  Substance evolves toxic fumes, wear self-contained breathing apparatus

Personal Precautions Wear protective clothing as per section 8
Immediate Actions Use appropriate containment to avoid environmental contamination (S57)
Clean Up Actions Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete
Special Precautions Wear protective clothing as per section 8
Handling

Wear protective clothing as per section 8 Avoid contact with skin and eyes (S24/25) Eyewash bottles should be available

Storage Keep only in the original container in a cool, well ventilated place (S3/9/49)
Protect from heat
Exposure controls No special precautions are required for this product
Occupational exposure controls Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended)

                                                          

Gloves                          Goggles                        suit                    No_Smoking

Odour Odourless
Appearance Pink Liquid , soluble in water
pH 11.3 -11.8 at 100 % concentration
Boiling point 00 °C at 760 mm /Hg
Vapour pressure not known
Vapour density not applicable
Freezing point <0 °C at 760 mm/Hg
Completely soluble in water
Specific gravity (water=1) 1.2 - 1.3

-   This article is considered stable under normal conditions
-   Avoid contact with acid
-   Incompatible with acid, Contact with acids liberates toxic gas (R31)
-    See Section 5

Toxicological information No experimental data available
Inhalation Not applicable
Contact with skin In cases of severe exposure, severe irritation may develop
Contact with eyes May cause severe irritation
May cause pain
Ingestion Toxic if swallowed (R25)
Carcinogenicity No evidence of carcinogenic effects
Mobility Completely soluble in water
Persistence and Biodegradability Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently biodegradable.
Bioaccumulation Potential Bioaccumulation of the components in this product is insignificant.
Other Adverse Effects No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment.
Disposal considerations Do not discharge into drains or the environment, dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation

 -  Not classified as hazardous for transport

Classification and labeling

Contains Benzothiazol-2-thiol.  May produce an allergic reaction.Cooling Water Treatment 15 Regulatory information

Risk Phrases Toxic if swallowed (R25)
Safety Phrases Wear suitable protective clothing, eye/face protection and gloves (S36/37/39)
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) This material and its container must be disposed of in a safe way (S35)

Text of R and S phrase codes used  in  this safety data sheet:-  R25: Toxic I f swallowed;  R43: May  cause  sensitisation by  skin  contact;   The  information  provided  about  the product  on  this  Safety  Data  Sheet  has  been  compiled  from knowledge of the individual constituents.The data given here  is  based  on current knowledge and experience. This Safety Data Sheet describes the product.In terms of safetyr equirements   and   does   not   signify  any   warranty   with  regard  to  the  product's  properties  The  data  given  here  only  applies  when  product  used for proper application(s). The product  is  not  sold  as  suitable for  other applications  -   usage   in  such  may  cause  risks  not   mentioned   in   this  sheet.  Do  not  use  for  other application (s) without seeking advice from manufacturer

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.
 

Request the signed SDS as PDF

Technical bulletin

Open technical bulletin

ROCCOR NB RXSOL  WITH INDICATOR.
RXSOL-40-4034-025

Scale and corrosion inhibitor with indicator
Chilled Closed Circuit Water Treatment

 
Introduction:-
RXSOL-40-4034-025 is a unique formulation with organic Corrosion Inhibitors , Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature.It is a concentrated liquid ,also used as a corrosion inhibitor ( Protects all the metals including cast iron , mild steel , copper etc)

Note:-The stable oxide film that is formed by RXSOL-40-4034-025 prevents corrosion caused by electrolytic action between dissimilar metals used in the system .RXSOL-40-4034-025 has been field tested and found to have no detrimental effects on non metallic substances such as seals, glands, packing, hoses, gaskets etc., normally used in these system .
 
Application - SDG*Sets:- Internal combustion engines closed circuit cooling system compressor cooling system RXSOL-40-4034-025 incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.
 
Advantages:-
1. Prolong the life of equipment by keeping scale and corrosion free. Since RXSOL-40-4034-025 is alkaline and so will suppress acid corrosion, which would otherwise result in corrosion damage such as pitting. However, the alkalinity control is such that even if the product is accidentally overdosed, the pH of the water will remain within limits. The metals which would be affected by extremes of alkalinity or acidity are protected.
2. Improves generating cooling efficiency by maintaining a clean heat transfer
3. Corrosion protection by using superior corrosion inhibitor.
4. Reduced maintenance and down time.
6. Friendly with Metals (Like steel, Copper, Aluminum, all alloys) & Non-metal (Rubber, Hoses, Gasket etc.)
 
Note:-
In cases where systems are contaminated with oil and/or scale they should be cleaned before starting to apply RXSOL-40-4034-025 .There are suitable RX BRAND products to carry out the cleaning. Degreasing should be carried out using RXSOL-16-1005-025 and descaling by using RXSOL-16-1008-025.
 
Specification:-

Colour

Pink

Sp. Gravity

1.2 to 1.3

pH

Alkaline ( 11.3 - 11.8 )

Odour

Odourless

Boiling Point

100 degre C

Solubility

100% in water

Freezing Point

17 degree C

Handling:- RXSOL-40-4034-025 is an alkaline product & should be handled like other chemical Avoid contact with Eyes, Skin ,in case of contact ,wash with copious amounts of water immediately.

General Recommendation

Nitrite (as PPM NO2) 

0

100-200

300-600

700-900

1100-1300

1440-2400

RXSOL-40-4034-025/1000L

13.0

11.3

8-10

5-7

1.5-3.5

0

Method Of Use:-
1. Properly clean the system with water and alkaline liquid , if necessary.
2. Add 0 .15-1.5 % of  RXSOL-40-4034-025  in system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any standard RXSOL test kit for Nitrite, Chloride test also helps to detect excess contamination to maintain accepted levels .when the product is dosed as recommended limit By buffering action of 1. Properly clean the system with water and alkaline liquid , if necessary.
2. Add 0 .15-1.5 % of  RXSOL-40-4034-025  in system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any standard RXSOL test kit for Nitrite, Chloride test also helps to detect excess contamination to maintain accepted levels .when the product is dosed as recommended limit By buffering action of  RXSOL-40-4034-025 , pH should be maintained between 8.3 and 10 by the treatment.

Note:- Initial dosage for an untreated system is 9 litres of   RXSOL-40-4034-025  / 1000 litres of untreated distilled water.This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4034-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval .pH should be maintained between 8.3 and 10 by the treatment.

Availability

ROCCOR NB RXSOL With Indicator Corrosion Inhibitor manufacturer supplier distributor in Mumbai, Kandla, Surat Gujrat Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Barka Muscat Oman, Kenya Africa. Get the best quality of ROCCOR NB RXSOL With Indicator at a competitive price from us. We have ready stock of ROCCOR NB RXSOL With Indicator Cooling Water Corrosion Inhibiotr in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches