RXSOL CHEMO PHARMA International Navi Mumbai, India

Products

7,087 products across 101 categories for marine, industrial, water treatment and laboratory use.

Browse all products Product catalogue

Test Kit For Water

SULFATE TEST KIT

This method is based on the precipitation of sulfate ion in such a manner as to form compound sulfate crystals of uniform size.
Part number
RXSOL-62-6198-001
Brand
RXSOL
SULFATE TEST KIT

Overview

Turbidimetric Photometric Method (0-50ppm)

Principle / Concept  

This method is based on the precipitation of sulfate ion in a hydrochloric acid medium with barium chloride in such a manner as to form barium sulfate crystals of uniform size.  The glycerol sulfate solution is used to maintain proper crystal size, and control of the stirring and waiting times is necessary to obtain reproducible result.  The resultant turbidity is measured at a wavelength sensitive to turbidity on a photometer.  The blank serves to partially cancel out interferences due to color and suspended matter. 

Apparatus Required :::  

Filter photometer complete with assorted laboratory glassware.  ::: RXSOL-62-6198-001 doesn't include this apparatus

Chemicals Required

Glycerol Sulfate Solution   ::: Part No.  RXSOL-62-6198-002    http://rxmarine.com/Glycerol-Sulfate-Solution
Barium Chloride (Natural )  Solution  ::: Part No. RXSOL-60-6263-250  rxmarine.com/Barium-Chloride-Solution
Sulfate Standard  ::: Part No.  RXSOL-62-6198-003   http://rxmarine.com/Sulfate-Standard-Solution

Applications

This procedure uses a wavelength of 420 nm and a cell with a light path of approximately 10-mm. First prepare a calibration curve for the photometer using successive dilutions of the sulfate standard to adequately cover the range of sulfate in the samples to be tested.  The dilutions of the standard should be treated in exactly the same manner as that shown below for analysis of the water samples.  Using a 50-ml plastic graduate, add 50 ml of sample to a 125-ml glass flask. Pipet 10 ml of glycerol sulfate solution into the flask and swirl the solution. Pipet 5 ml of distilled water into the flask, swirl the solution and use this solution to set the photometer at zero absorbance. Discard the solution and rinse the flask with distilled water. Into a second 50-ml sample, pipet 10 ml of glycerol sulfate solution and swirl. Adjust the temperature of the sample to 70 to 75F, and pipet 5 ml of neutral barium chloride solution into the same flask. Stir the solution by rotating a rubber paddle between the palms at moderate speed for exactly five seconds. Wait exactly five minutes, and then measure the absorbance on the photometer. 

Calculation of Results  The sulfate concentration in parts per million as SO4  is obtained by reference to the prepared sulfate calibration curve. 

Limitations of Test 

Color or large amounts of suspended matter will interfere with this method,  but some suspended matter may be removed by filtration. Also the presence of color and suspended matter is compensated for to some extent by the blank determination. Silica in excess of 500 ppm will interfere, and in samples containing large amounts of organic material, it may not be possible to precipitate barium sulfate satisfactorily.  

Characteristics and notes

Water Testing Procedures Manual ( Full Range Lab testing   Methods with standard  composition ratio Of Reagents  ::: Available with us  at 2700 INR or 54 US$ or 207 AED

SULFATE TEST

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger. 

Safety and SDS

Read the safety data sheet before handling. Wear suitable gloves and eye protection.

View safety data sheet
Product Name RXSOL-60-6198-500
Product Type Sulfate Indicator Solution

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA 

Phone +91 22 65113333 / 5555 / 9999
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email rxsolchemicals@gmail.com

    

SARA 313 Component  CAS Number Percent Comp. Dimension
 
Exposure
 Limits
 
Barium Chloride  CAS# 10326- 27-9 9 -10 W/V OSHA PEL
 0.89 mg/mƒ
Hydrochloric Acid CAS# 7647-01-0  1 - 6% V/V OSHA PEL (C)
5 ppm, (C) 7
mg/mƒ
 
Water, Deionized ASTM Type II CAS# 7732-18-5 85-96% V/V None
Established

May cause irritation and burns. May be harmful if swallowed. Avoid breathing vapor or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed.

Emergency Overview:Ingestion may Cause Gastronintestinal Disturbances. May Cause Eye
Irritation, Redness and Pain.

Inhalation:Not Expected to Be a Health Hazard.

Ingestion:Large Oral Doses may Cause Gastrointestinal Disturbances.

Skin:No Adverse Effects Expected.

Eye Contact:May Cause Irritation, Redness and Pain.

Chronic Exposure:No Information Found.

Aggravated by Exposure:No Information Found.

May cause irritation and burns. May be harmful if swallowed. Avoid breathing vapor or dust. Use with adequate ventilation. Avoid contact with eyes, skin, and clothes. Wash thoroughly after handling. Keep container closed. 

SKIN:

Remove contaminated clothing. Wash exposed area with soap and water. if irritation persists, seek medical attention.

EYES:  Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally.
Seek Medical Aid. INHALATION: Remove to fresh air. If not breathing, give artificial
respiration. If breathing is difficult, give oxygen
INGESTION:  Give several glasses of milk or water. Vomiting may occur spontaneously, but DO NOT INDUCE! Never give anything by mouth to an unconscious person.

Fire Extinguisher Type:

Any means suitable for extinguishing
surrounding fire

Fire / Explosion Hazards: None
Fire Fighting Procedure: Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and clothing.

Absorb spill with inert material, then place in a chemical waste container. Neutralize with a weak base.

Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified in Section 8. Spills: Contain and Recover Liquid when Possible

Store in a cool dry place. Do not get in eyes, on skin, on clothing. Wash thoroughly after handling. Keep out of direct sunlight, away from heat, water and incompatible materials. Containers may be

Respiratory Protection

None required

Ventilation Local 
OTHER Mechanical 
Protective Gloves Wear appropriate gloves to prevent skin exposure
EYE PROTECTION Splash Goggles 
Other Protective Equipment  Wear appropriate clothing to prevent
skin exposure

       

BOILING POINT   Information not available
VAPOR PRESSURE     Information not available
MELTING POINT   Information not available
VAPOR DENSITY     Information not available
EVAPORATION RATE  Information not available
Appearance /Odors Clear colorless liquid/no   
Flash Point  Information not available
Specific Gravity hazardous when empty. odor ~ 1
Percent Volatile by  >99%
Evaporation Standard  
Auto Ignition Temp

Not applicable

Lower Flamm. Limit in Air Not applicable
 
Upper Flamm. Limit in Air  Not applicable
 
Solubility in Water Soluble

STABILITY

Stable

CONDITIONS TO AVOID

 Avoid Light
 

MATERIALS TO AVOID

 Halides, ammonia, phosphates, bases

HAZARDOUS DECOMPOSITION PRODUCTS

HCL Fumes, Chlorine

HAZARDOUS POLYMERIZATION

 Will Not Occur
 
Conditions to Avoid  None known

Carcinogenic References: Hydrogen Chloride - IARC Category 3, NTP Carcinogen - Known:
No

Environmental Fate: When Released into the Soil, this Material is Not Expected to Biodegrade.
When Released into the Soil, this Material may Leach into Groundwater.

Dilute with Water and Flush to Sewer if Local Ordinances Allow, Otherwise, Whatever Cannot be Saved for Recovery or Recycling should be Managed in an Appropriate and Approved Waste
Disposal Facility. Processing, Use or Contamination of this Product may Change the Waste Management Options. State and Local Disposal Regulations May Differ from Federal Disposal Regulations. Dispose of Container and Unused Contents in Accordance with Federal, State and Local Requirements.

DOT Classification: UN1789, Hydrochloric Acid Solution, 8, PG III

DOT Regulations may change from time to time. Please consult the most recent D.O.T. regulations.

Chemical Inventory Status –
Part 1:Ingrdient
Barium Chloride (10361-37-2)
Hydrogen Chloride (7647-01-0)
TSCA                  Yes           YES
EC                       Yes           YES
Japan                 YES           YES
Australia            Yes            YES

Chemical Inventory Status –
Part 2:Ingredient
Barium Chloride (10361-37-2)
Hydrogen Chloride (7647-01-0)
Korea                 Yes          YES
DSL                    Yes          YES
NDSL                 No            NO
Phil.                    Yes          YES

Federal, State & International Regulations –
Part 1: Ingredient.
Barium Chloride (10361-37-2)
Hydrogen Chloride (7647-01-0)
RQ          No           5000
TPQ        No            500
List          NO          YES
Chemical Catg:    BARIUM COMP  No

Federal, State &
International Regulations –
Part 2:Ingredient
Barium Chloride (10361-37-2)
Hydrogen Chloride (7647-01-0)
CERCLA        NO           5000
261.33            No           NO
8(d)                  No          NO

Chemical Weapons Convention: No
TSCA 12 (b):No

Overexposure symtoms: Corrosive effects.: Acute-Irritation possible to skin, eyes, lungs, mucous membranes, and GI tract. Chronic- none known. Conditions aggravated/Target organs: Persons with preexisting skin, eye, or respiratory disorders may be more susceptible. May be Toxic by ingestion. Ingestion may cause severe abdominal pain, violent purging with bloody stool, confusion, paralysis, For eye contact, flush with plenty of water for

                                                              Flammability


Health                                                                                                      Reactivity

                                                                                          

Revisions

NFPA
7/30/2010  0.1 updated msds to 16 section from 10
section msds. STN
   0

The information herein is believed to be accurate and is offered in good faith for the user's consideration and investigation. No warranty either expressed or implied is made for the completeness or accuracy of the information whether originating from the above mentioned company or not. Users of this material should satisfy themselves by independent investigation of current scientific and medical knowledge that the material

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Request the signed SDS as PDF

Availability

SULFATE TEST KIT manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of SULFATE TEST KIT at a competitive price from us. We have ready stock of SULFATE TEST KIT in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Our stock points and branches